FREE STUDY · 5 MIN LESSON
dB Math, OTDR & Loss Budgets
Read this lesson without an account. To use narrated cards and save your progress in the app, create a free account or sign in. No payment is required for the free modules. Knowledge practice does not replace approved training or any skills evaluation your certifying body requires.
dB and dBm: Ratio and Reference
- dB is a power ratio; dBm references 1 mW
- 3 dB loss leaves approximately half the power
- 10 dB loss leaves one-tenth
Measuring End-to-End Insertion Loss
- A source and power meter or OLTS measures insertion loss
- Set the reference using compatible known-good cables
- Use the documented one-, two- or three-cable method
- Compare the measurement with the project criterion
OTDR Trace: Finding Events & Distances
- OTDR uses pulses and returned light
- Trace analysis estimates event locations and loss
- Dead zones and resolution can hide events
- Measure end-to-end insertion loss separately
Estimating Loss and Applying Project Criteria
- Estimate fiber, connection-pair, splice and passive-device losses
- Use the applicable component and project specifications
- Consider the reference method and measurement uncertainty
- Check receiver limits and other project requirements
Quick Self-Check
Check this point against current official guidance before relying on it.
- Given:2 connection pairs at 0.5 dB;1 splice at 0.1 dB;0.5 km at 0.35 dB/km
- Connections:1.0 dB;splice:0.1 dB;fiber:0.175 dB
- Total:1.275 dB, approximately 1.28 dB
- These are supplied example values, not universal limits